Project

General

Profile

Actions

Defect #44349

open

VRV DICz Bug related to thermo field setting

Added by Ravindra Rathore about 3 hours ago.

Status:
Resolved
Priority:
Normal
Assignee:
-
Category:
Issues
Target version:
-
Resolution:
Affected version:

Description

while transferring the code from 2300E30A to 18013303 two extra setting related to thermo off tap H and monitoring were copied because of that while doing the FCT it was checking for 7 setting but since only 5 field setting were kept at at the EEPROM so the there was mismatch while checking the field setting at the time of FCT so we need to remove the two extra field setting and since while transffering only enum value was transffered no any logic was transffered so there was no impact on the overall code


Files

dicz.xlsx (66 KB) dicz.xlsx Ravindra Rathore, 2026-08-18 06:34

No data to display

Actions

Also available in: Atom PDF